In the 20-years old history of the company, products are continuously redesigned and new ones introduced to market. However, the process also includes streamlining and phasing out of items which can not be produced anymore because of technical reasons or due to replacement by new products. In the following table there are phased-out products together with their replacements, if available.
For the sake of clarity, the table only includes parts of the control system (PLCs, I/O modules, room units, converters etc.), not the peripherals. For these, replacement is easier and customers can usually handle it themselves.
Please contact technical support if in doubt, because the replacement solution may vary and depend on the installation context. Not all features of the old product may be used, which allows functional replacement even in case of partial compatibility. For items like LCD displays and industrial PCs, which are replaced by new models at a fast rate, we are able to recommend a replacement by another manufacturer.
Our goal is that the lifetime of the control system does not limit the lifetime of the entire technology. We are committed to protecting your investment and are always ready to search for a solution that will maintain or extend the time the technology can operate safely and reliably at minimal cost.
Old product | Replacement | Technical differences | Phased out |
ECIO2 | ICIO205 | Not a 100% replacement: an application software must be created for ICIO205, no automatic routing, more slaves must be programmed in the application | 2017 |
FC010 | FCR010 | New housing, new operating conditions | 2019 |
FC013 | FCR013 | New housing, new operating conditions | 2019 |
FC015 | FCR015 | New housing, new operating conditions | 2019 |
FC020 | - | No replacement. In some applications, FCR013 + UC013 can be used. | 2020 |
HT100 | HT300 | Larger aperture, power only 24 V DC, menu must be converted in the editor | 2015 |
HT101 | HT300 | Larger aperture, power only 24 V DC, menu must be converted in the editor | 2021 |
HT102 | HT300 | Larger aperture, power only 24 V DC, menu must be converted in the editor | 2021 |
HT103 | HT300 | Larger instalation aperture, power 24 V DC only, menu must be converted in the editor | 2023 |
HT104 | HT300 | Larger instalation aperture, power 24 V DC only, menu must be converted in the editor | 2023 |
ICIO200 | ICIO205.2 | Full backward compatibility | 2020 |
ICIO205 | ICIO205.2 | Full backward compatibility | 2022 |
IMIO100 | IMIO105.2 | Full backward compatibility | 2020 |
IMIO105 | IMIO105.2 | Full backward compatibility | 2022 |
IMIO110 | IMIO110.2 | Full backward compatibility | 2022 |
IPC00... | - | No direct replacement | 2014 |
IPC05... | - | No direct replacement | 2014 |
IPC07... | - | No direct replacement | 2014 |
IPC08... | - | No direct replacement | 2014 |
IPC10... | - | No direct replacement | 2014 |
IPC12... | - | No direct replacement | 2014 |
IPC15... | - | No direct replacement | 2014 |
IPC17... | - | No direct replacement | 2014 |
IPC19... | - | No direct replacement | 2014 |
IPLC520 | - | No direct replacement | 2016 |
IRISC... | - | No direct replacement | 2014 |
LCD... | - | No direct replacement | 2015 |
M.../A | - | No replacement. Modules with Advantech communication protocol. | 2015 |
M011 | R012 | New housing, new operating conditions | 2011 |
M012 | R012 | New box, new operating conditions | 2017 |
M020 | R025 | New box, new operating conditions | 2016 |
M025 | R025 | New box, new operating conditions | 2016 |
M031 | R031 | New box, new operating conditions | 2016 |
M035 | R035 | New box, new operating conditions | 2016 |
M036 | R035 | Full backward compatibility | 2017 |
M040 | - | No direct replacement (combination of R035 and a WiFi AP) | 2016 |
M050 | - | No direct replacement, combination of R035 and a WiFi AP | 2012 |
M080 | R080 | Full backward compatibility (removable cable with a USB-A connector) | 2021 |
M085 | R085 | New box, new operating conditions | 2017 |
M086 | R086 | New box, new operating conditions | 2017 |
M090 | R091 | Support of DALI2. SW backwards compatible. New housing, 4 DIN module instead of 2 DIN. | 2016 |
M095 | R095 | New box - 4 DIN module instead of 2 DIN., new operating conditions. | 2017 |
M096 | R096 | New box - 4 DIN module instead of 2 DIN., new operating conditions. | 2017 |
M200 | R220 | New housing, 4 DIN module instead of 2 DIN. New operating conditions. 8 DO more. | 2019 |
M210 | R220 | Modbus map fully compatible with M210. 12 DO instead of 8 DO. New box, new operating conditions | 2019 |
M215 | - | No replacement, R220 has no manual intervention, otherwise compatible, new box, new operating conditions | 2016 |
M300 | R320 | New box - 4 DIN module instead of 2 DIN modules, new operating conditions. Small terminals instead of big ones. | 2021 |
M312 | R312 | New box, new operating conditions | 2019 |
M313 | R313 | New box, new operating conditions | 2020 |
M320 | R320 | New housing, new operating conditions. Small terminals instead of big ones. | 2019 |
M325 | - | No replacement, R320 has no manual intervention, otherwise compatible, new box and terminals, new operating conditions | 2016 |
M400 | R420 | New box - 6 DIN module instead of 4 DIN modules. New terminal layout. Modbus table not 100% compatible with that of M400. | 2019 |
M401 | R420 | New box - 6 DIN module instead of 4 DIN modules. New terminal layout. Modbus table not 100% compatible with that of M401. | 2019 |
M410 | - | No replacement. (AC 230 V inputs) | 2019 |
M411 | - | No replacement. (AC 230 V inputs) | 2019 |
M420 | R420 | Small terminals instead of big ones. Common potentials for 8 and 8 inputs now not galvanically separated. New housing, new operating conditions | 2019 |
M430 | R430 | New housing, new operating conditions | 2019 |
M500 | R500 | New housing, new operating conditions. Small terminals instead of big ones. Now DIP for 0…20 mA also at AI 5-8 | 2020 |
M504 | R560 | New housing, new operating conditions. Small terminals instead of big ones. Resistance measuring range added. Only 0…10 V for voltage measuring range. | 2021 |
M550 | R560 | Terminals changed, Modbus map incompatible! | 2012 |
M560 | R560 | New housing, new operating conditions. Small terminals instead of big ones. Now DIP for 0…20 mA also at AI 5-8 | 2018 |
M580 | - | No replacement. In some applications, R560 with DHS... probes can be used, SW modification required | 2016 |
M600 | - | No direct replacement | 2012 |
M610 | R610 | Teminal layout changed (unification with other modules), new housing, new operating conditions | 2020 |
M620 | - | No replacement (0...20 mA output) | 2023 |
M700 M700/A | R710 | Terminal layout changed. New housing, new operating conditions | 2012 |
M710 | R710 | Terminal layout changed. New housing, new operating conditions | 2021 |
mark100 | mark220LX | Larger dimensions, 6 DIN modules rather than 2 DIN modules | 2023 |
mark125 | mark130.2 | Full backward compatibility | 2021 |
mark130 | mark130.2 | Full backward compatibility | 2022 |
mark150/485 | - | No direct replacement, combination of a PLC and corresponding I/O modules | 2023 |
mark220 | mark220LX | Full backward compatibility | 2021 |
mark320 | mark320LX | Full backward compatibility | 2021 |
markMX | markMX.3 | Full backward compatibility | 2021 |
markMX.2 | markMX.3 | Full backward compatibility | 2023 |
MCIO | RCIO | Terminals changed, Modbus map incompatible! | 2011 |
MCIO2 | RCIO | Only redesign of the cover | 2020 |
MMIO | RMIO | New terminal layout. DI/AI/AO/DO6,7 now terminals up to 1,5 mm², SSR also for DC load, addressing using DIP | 2019 |
MT020 | - | No replacement. | 2019 |
MTala010 | - | No replacement. | 2017 |
MW240 | MW240-B | Full backward compatibility | 2017 |
MXIO | RXIO | Only redesign of the cover | 2018 |
MYIO | - | No replacement. | 2015 |
R020 | R025 | Full backward compatibility | 2020 |
R031 | R035 | Full backward compatibility | 2020 |
R040 | - | No direct replacement, combination of R025 and a WiFi AP | 2023 |
R090 | R091 | Full backward compatibility, more functions added | 2019 |
S010-Mbus | ... | Depending on number of meters R095, R096, or a 3rd party converter | 2011 |
TOUCH... | - | No direct replacement | 2014 |
UC011 | UC010 | Note that the RS485 is not galvanically separated. No problem for most applications. | 2018 |
UC095 | UC905 | Attention: Different terminal layout (standardization with other UI...), check firmware version | 2019 |
UC100 | UC102 | Fully backward compatible, plus 2× DI | 2015 |
UC150 | - | No direct replacement, combination of UC102 and a Modbus router | 2022 |
UC250 | - | No direct replacement, combination of UC200 and a Modbus router | 2022 |
UCWEB | - | No replacement. | 2020 |
UI041 | UI011 | Full backward compatibility (all UI... now have a rH sensor) | 2018 |
UI042 | UI012 | Full backward compatibility (all UI... now have a rH sensor) | 2018 |
UI045 | UI020 | Full backward compatibility (all UI... now have a rH sensor) | 2018 |
UI061 | UI051 | Full backward compatibility (all UI... now have a rH sensor) | 2019 |
UI062 | UI052 | Full backward compatibility (all UI... now have a rH sensor) | 2019 |
UI065 | UI055 | Full backward compatibility (all UI... now have a rH sensor) | 2019 |
UI081 | UI071 | Full backward compatibility (all UI... now have a rH sensor) | 2019 |
UI082 | UI072 | Full backward compatibility (all UI... now have a rH sensor) | 2019 |
UI085 | UI075 | Full backward compatibility (all UI... now have a rH sensor) | 2019 |
UI09... | UI9... | Attention: Different terminal layout (standardization with other UI...), functionally compatible | 2017 |
UI410 | - | No replacement. | 2019 |
UI415 | UI416 | Attention: Different terminal layout (standardization with other UI...), functionally compatible | 2020 |
UI5... | - | No direct replacement, combination of UI... and a Modbus router | 2022 |
UI652 | - | No direct replacement, combination of power supply, UI052 and a Modbus router | 2022 |
UI672 | - | No direct replacement, combination of power supply, UI072 and a Modbus router | 2022 |
UI682 | - | No direct replacement, combination of power supply, UI082 and a Modbus router | 2022 |